PowerXchanger Step Down 220 volt to 120 Volt 60Hz step down voltage converter 2340 Watts 21.8 Amp 12060EX-21
- Step Down 220 volts 50 hz to 120 volts 60 hz transformer converter for use Overseas in countries with 220 volts 50 hz power to use USA 110 / 120 volts 60 hz Appliances and electronics
- Input Range: 180Vac-285Vac
- Input Frequency: 50Hz/60Hz
- Output: 100V-110V-115V-120V (Selectable)
- Output Frequency: 50Hz/60Hz (Selectable)
- 2600VA/2340W
- Maximum Output Current: 21.8 Amp (Your application power requirement should not exceed maximum output current)
PowerXchanger Step Down 220 volt to 120 Volt 60Hz step down voltage converter 2340 Watts 21.8 Amp 12060EX-21
Overview
This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With the Converter, you can protect your equipment from most of the power problems, including power sags, power surges, and line noise, etc. With the common neutral topology, the Converter provides internal connection from AC I/P neutral to AC O/P neutral; thus, it does not need to use an isolation transformer to provide 0 volt from AC I/P neutral to O/P neutral. This feature will reduce the interference to loads of communication or video system.
Features
With outstanding performance & reliability, the unique benefits of the Converter include the following:
- Common Neutral, Double Conversion Topology (O/P Neutral to I/P Neutral is 0 volts normally)
- Input Power Factor correction
- Low Noise Smart Cooling Fan Design
- High Efficiency, New Full-bridge Inverter Design
- Full Function LCD Display
- Automatic Restart of Loads After Overload Shutdown
- AC Input Generator Compatible
- Remote Emergency Power Off
Specification
Output | |
Capacity | 2600VA/2340W |
Output Voltage | 100V/110V/115V/120V Selectable |
Output Current-Amps @ 60Hz |
21.8 Amp |
OUTPUT PEAK CURRENT (<250mS) | 60 Amp |
Voltage Regulation | ±2% of selected output voltage |
Output Frequency (sync to mains) |
50±0.05Hz or 60±0.06Hz (Auto-Synchronized to Mains) |
Output Frequency (not sync to mains) |
50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz |
Crest Factor | 3:1 |
Voltage Waveform | Sine Wave |
Output Distortion (Resistive Load) | <2% |
Output Distortion (Reactive Load) | <3% |
Non-Linear Peak Current for 30 sec. | 42A |
Standby Power | 27W |
Total Harmonic Distortion | <3% (at full resistive load) |
Output EMI Filter | N/A |
Output RFI Filter | 30Mhz - 1000Mhz |
Clamp Level | 200V PEAK |
Protection | |
Over load Protection | 100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p; > 130%, alarm for 2 seconds, then shutdown o/p; |
4A | Output protected from short circuit by pulsating type Auto-Restart time: 30 seconds |
Input | |
Voltage Range | 180V~285Vac |
Maximum Continuous Load | 2340W |
Maximum Peak Load | 3000W |
Input Current | 15 Amp |
Input Frequency Range | 45Hz ~ 70Hz |
Phase | Single |
Noise Filtering | Full-Time EMI/RFI Filtering |
Input EMI Filter | 150Khz -30Mhz (class A) |
Input RFI Filter | 30Mhz - 1000Mhz (class A) |
Over Current Protection | By Re-Settable Over Current Protector |
Voltage Range | 180 V ~ 285 Vac |
Power Factor | ≧0.98 |
Audible Alarm | Over load alarm, Short-circuit alarm, Thermal alarm |
Inrush Surge Capacity | <100A, 3mS |
Voltage Interruption Ride Through |
10mS |
Efficiency | |
Efficiency | >89% |
Output Connection from Mains | |
Ground | Input and Output Ground Connected |
Neutral | Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required |
Indicators | |
LCD Control Panel | Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level Selectable Output Voltage and Output Frequency |
LED | N/A |
Output Compatibility | |
Output Compatibility with UPS | Yes |
Environmental and Safety | |
Operating Temp. | Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉) |
Transit/storage Temp. | -15℃ to 55℃ (5℉ to 131℉) |
Relative Humidity | 5 – 95% Non-Condensing |
Operating Altitude | 0 ~ 3000 Meters |
Moisture Sensitivity | Internal Fan |
Audible Noise | ≦45 dBA (at 1 meter from surface of unit) |
Cooling | |
Natural Ventilation | |
External Cooling Fan Control | Forced air cooling by internal fan |
Physical | |
Dimensions W×D×H | 51 × 20 × 18 cm 20.08 x 7.87 x 7.08 in |
Weight Net/Gross | 8.5 kg 18.74 lbs |
Shipping Dimension | 26.00 x 16.00 x 16.00 in 66.04 x 40.64 x 40.64 cm |
Shipping Weight | 28.00 lbs 12.70 kgs |
Others | |
Standard Accessories | Input Power Cords, Type F, Type G, Type I, Type M. |
Wall Mountable | No |
Warranty | 2 Years, Full Replacement |
Quality Control Standard | ISO9001 |
Approvals and Safety Markings | CE |